Filters
Variable Frequency Drives (VFD)
part#
description
manufacturer
C200-07600290A10101AB100
NIDEC C200-07600290A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series designed with air cooling. It operates on a supply voltage of 500Vac-690Vac (600Vac) and has dimensions of frame size 7 H21.93" x W10.63" x D11.02" (H557mm x W270mm x D280mm). This model offers a degree of protection of IP20 NEMA 1 and supports a rated current of 36A under normal duty and 29A under heavy-duty conditions. It utilizes the Modbus RTU communication protocol over a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 analog output (10Vdc; source; single-ended), 5 digital inputs (0-24Vdc; PNP/NPN) plus 1 additional digital input (0-24Vdc), and 2 digital outputs (one 50mA / 0-24Vdc; source; PWM and one 2A / 240Vac; source; relay contact type). Additionally, it includes 2 analog inputs (one 0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution and one 0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 30kW under normal duty and 22kW under heavy-duty, with a rated power of 40HP (normal duty) and 30HP (heavy-duty).
Nidec
Quick Quote
C200-07600190A10101AB100
NIDEC C200-07600190A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series designed with air cooling. It operates on a supply voltage of 500Vac-690Vac (600Vac) and has dimensions of frame size 7 H21.93" x W10.63" x D11.02" (H557mm x W270mm x D280mm). This model offers a degree of protection of IP20 NEMA 1 and supports a rated current of 23A under normal duty and 19A under heavy-duty conditions. It utilizes the Modbus RTU communication protocol over a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 analog output (10Vdc; source; single-ended), 5 digital inputs (0-24Vdc; PNP/NPN) plus 1 additional digital input (0-24Vdc), and 2 digital outputs (one 50mA / 0-24Vdc; source; PWM and one 2A / 240Vac; source; relay contact type). Additionally, it includes 2 analog inputs (one 0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution and one 0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 18.5kW under normal duty and 15kW under heavy-duty, with a rated power of 25HP and 20HP, respectively.
Nidec
Quick Quote
C200-07500550A10101AB100
NIDEC C200-07500550A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series designed with air cooling. It operates on a supply voltage of 500Vac-575Vac, with dimensions of frame size 7 H21.93" x W10.63" x D11.02" (H557mm x W270mm x D280mm), and offers a degree of protection of IP20 NEMA 1. The rated current is 73A for Normal duty and 55A for Heavy-duty applications. It supports Modbus RTU communication protocol over a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 x digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) plus 1 x digital output (2A / 240Vac; source; relay contact type). Additionally, it includes 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 45kW for Normal duty and 37kW for Heavy-duty, with a rated power of 60HP for Normal duty and 50HP for Heavy-duty.
Nidec
Quick Quote
C200-07600240A10101AB100
NIDEC C200-07600240A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series designed with air cooling. It operates on a supply voltage of 500Vac-690Vac (600Vac) and has dimensions of frame size 7 H21.93" x W10.63" x D11.02" (H557mm x W270mm x D280mm). This model offers a degree of protection of IP20 NEMA 1 and supports a rated current of 30A under normal duty and 24A under heavy-duty conditions. It utilizes the Modbus RTU communication protocol over a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 x digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) plus 1 x digital output (2A / 240Vac; source; relay contact type). Additionally, it includes 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 22kW under normal duty and 18.5kW under heavy-duty, with a rated power of 30HP (normal duty) and 25HP (heavy-duty).
Nidec
Quick Quote
C200-07500440A10101AB100
NIDEC C200-07500440A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series, designed with air cooling. It operates on a supply voltage of 500Vac-575Vac, with dimensions of frame size 7 H21.93" x W10.63" x D11.02" (H557mm x W270mm x D280mm), and offers a degree of protection of IP20 NEMA 1. The rated current is 53A for Normal duty and 44A for Heavy-duty. It supports Modbus RTU communication protocol and is designed for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 x digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) plus 1 x digital output (2A / 240Vac; source; relay contact type). Additionally, it includes 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 37kW for Normal duty and 30kW for Heavy-duty, with a rated power of 50HP for Normal duty and 40HP for Heavy-duty.
Nidec
Quick Quote
C200-07401000A10101AB100
NIDEC C200-07401000A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series designed with air cooling. It operates on a supply voltage of 380Vac-480Vac, specifically 400Vac / 415Vac, and accommodates a 3-phase input network with a frequency range of 45-66 Hz on the supply input and an output frequency range of 0-550 Hz. This model features a frame size 7 with dimensions of H21.93" x W10.63" x D11.02" (H557mm x W270mm x D280mm) and offers a degree of protection rated at IP20 NEMA 1. It is rated for a current of 112A under normal duty and 100A under heavy-duty conditions. Communication is facilitated through Modbus RTU protocol. The ambient air temperature for operation ranges from -20°C to +60°C. It includes 1 analog output (10Vdc; source; single-ended), 5 digital inputs (0-24Vdc; PNP/NPN) plus 1 additional digital input (0-24Vdc), and 2 digital outputs (one 50mA / 0-24Vdc; source; PWM and one 2A / 240Vac; source; relay contact type). For analog inputs, it features 1 input for 0-20mA / 4-20mA / 0-10Vdc (single-ended; 11-bit conversion resolution) and another for 0-10Vdc (single-ended; 11-bit conversion resolution). The rated active power is 55kW for normal duty and 45kW for heavy-duty, with a rated power of 75HP for both conditions.
Nidec
Quick Quote
C200-07400770A10101AB100
NIDEC C200-07400770A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series, designed with air cooling. It operates on a supply voltage of 380Vac-480Vac (400Vac / 415Vac) and has dimensions of frame size 7 H21.93" x W10.63" x D11.02" (H557mm x W270mm x D280mm). This model offers a degree of protection of IP20 NEMA 1 and supports a rated current of 94A for Normal duty and 77A for Heavy-duty. It utilizes the Modbus RTU communication protocol over a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation is between -20°C and +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 x digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) plus 1 x digital output (2A / 240Vac; source; relay contact type). Additionally, it includes 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 45kW for Normal duty and 37kW for Heavy-duty, with a rated power of 60HP for both Normal and Heavy-duty applications.
Nidec
Quick Quote
C200-07200830A10101AB100
NIDEC C200-07200830A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series designed with air cooling. It operates on a supply voltage of 200Vac-240Vac (220Vac / 230Vac) and has dimensions of frame size 7 H21.93" x W10.63" x D11.02" (H557mm x W270mm x D280mm). This model offers a degree of protection of IP20 NEMA 1 and supports a rated current of 117A for Normal duty and 83A for Heavy-duty applications. It utilizes Modbus RTU for communication and is designed for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 x digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) plus 1 x digital output (2A / 240Vac; source; relay contact type). Additionally, it includes 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 30kW for Normal duty and 22kW for Heavy-duty, with a rated power of 40HP for Normal duty and 30HP for Heavy-duty.
Nidec
Quick Quote
C200-07200750A10101AB100
NIDEC C200-07200750A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series designed with air cooling. It operates on a supply voltage of 200Vac-240Vac (220Vac / 230Vac) and has dimensions of frame size 7 H21.93" x W10.63" x D11.02" (H557mm x W270mm x D280mm). This model offers a degree of protection of IP20 NEMA 1 and supports a rated current of 94A for Normal duty and 75A for Heavy-duty applications. It utilizes Modbus RTU for communication and is designed for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 x digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) plus 1 x digital output (2A / 240Vac; source; relay contact type). Additionally, it includes 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 22kW for Normal duty and 18.5kW for Heavy-duty, with rated power of 30HP and 25HP, respectively.
Nidec
Quick Quote
C200-07200610A10101AB100
NIDEC C200-07200610A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series designed with air cooling. It operates on a supply voltage of 200Vac-240Vac (220Vac / 230Vac) and has dimensions of frame size 7 H21.93" x W10.63" x D11.02" (H557mm x W270mm x D280mm), with a degree of protection rated at IP20 NEMA 1. The rated current is 75A for Normal duty and 61A for Heavy-duty. It supports Modbus RTU communication protocol over a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 x digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) plus 1 x digital output (2A / 240Vac; source; relay contact type). Additionally, it includes 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 18.5kW for Normal duty and 15kW for Heavy-duty, with a rated power of 25HP for Normal duty and 20HP for Heavy-duty.
Nidec
Quick Quote
C200-06500350A10101AB100
NIDEC C200-06500350A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series, designed with air cooling. It operates on a supply voltage of 500Vac-575Vac, with dimensions of frame size 6 H15.39" x W8.27" x D8.94" (H291mm x W210mm x D227mm), and offers a degree of protection of IP20 NEMA 1. The rated current is 43A for Normal duty and 35A for Heavy-duty. It supports Modbus RTU communication protocol over a 3-phase input network, with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 x digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) plus 1 x digital output (2A / 240Vac; source; relay contact type). The analog inputs include 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 30kW for Normal duty and 22kW for Heavy-duty, with rated power of 40HP for Normal duty and 30HP for Heavy-duty.
Nidec
Quick Quote
C200-06500290A10101AB100
NIDEC C200-06500290A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series, designed with air cooling. It operates on a supply voltage of 500Vac-575Vac, with dimensions of frame size 6 H15.39" x W8.27" x D8.94" (H291mm x W210mm x D227mm) and offers a degree of protection of IP20 NEMA 1. The rated current is 34A for Normal duty and 29A for Heavy-duty. It supports Modbus RTU communication protocol and is designed for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 x digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) plus 1 x digital output (2A / 240Vac; source; relay contact type). The analog inputs include 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 22kW for Normal duty and 18.5kW for Heavy-duty, with rated power of 30HP for Normal duty and 25HP for Heavy-duty.
Nidec
Quick Quote
C200-06500230A10101AB100
NIDEC C200-06500230A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series, designed with air cooling. It operates on a supply voltage of 500Vac-575Vac, with dimensions of frame size 6 H15.39" x W8.27" x D8.94" (H291mm x W210mm x D227mm), and offers a degree of protection of IP20 NEMA 1. The rated current is 27A under normal duty and 23A under heavy-duty conditions. It supports Modbus RTU communication protocol over a 3-phase input network, with a network frequency of 45-66 Hz (supply input) and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 x digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) plus 1 x digital output (2A / 240Vac; source; relay contact type). Additionally, it has 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 18.5kW under normal duty and 15kW under heavy-duty, with a rated power of 25HP (Normal duty) and 20HP (Heavy-duty).
Nidec
Quick Quote
C200-06500190A10101AB100
NIDEC C200-06500190A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series, designed with air cooling. It operates on a supply voltage of 500Vac-575Vac, with dimensions of frame size 6 H15.39" x W8.27" x D8.94" (H291mm x W210mm x D227mm), and offers a degree of protection of IP20 NEMA 1. The rated current is 22A under normal duty and 19A under heavy-duty conditions. It supports Modbus RTU communication protocol over a 3-phase input network, with a network frequency of 45-66 Hz (supply input) and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 x digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) plus 1 x digital output (2A / 240Vac; source; relay contact type). Additionally, it includes 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 15kW under normal duty and 11kW under heavy-duty, with a rated power of 20HP (normal duty) and 15HP (heavy-duty).
Nidec
Quick Quote
C200-06500150A10101AB100
NIDEC C200-06500150A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series, designed with air cooling. It operates on a supply voltage of 500Vac-575Vac, with dimensions of frame size 6 H15.39" x W8.27" x D8.94" (H291mm x W210mm x D227mm), and offers a degree of protection rated at IP20 NEMA 1. The rated current is 17A under normal duty and 15A under heavy-duty conditions. It supports Modbus RTU communication protocol over a 3-phase input network, with a network frequency of 45-66 Hz (supply input) and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 additional digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) plus 1 x digital output (2A / 240Vac; source; relay contact type). The analog inputs include 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 11kW under normal duty and 7.5kW under heavy-duty, with a rated power of 15HP (normal duty) and 10HP (heavy-duty).
Nidec
Quick Quote
C200-06400470A10101AB100
NIDEC C200-06400470A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series, designed with air cooling. It operates on a supply voltage of 380Vac-480Vac (400Vac / 415Vac) and has dimensions of frame size 6 H15.39" x W8.27" x D8.94" (H291mm x W210mm x D227mm). This model offers a degree of protection of IP20 NEMA 1 and supports a rated current of 63A for Normal duty and 47A for Heavy-duty applications. It utilizes Modbus RTU for communication and is designed for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 additional digital input (0-24Vdc), and 2 digital outputs (one 50mA / 0-24Vdc; source; PWM and one 2A / 240Vac; source; relay contact type). Additionally, it includes 2 analog inputs (one 0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution and one 0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 30kW for Normal duty and 22kW for Heavy-duty, with a rated power of 40HP for Normal duty and 30HP for Heavy-duty.
Nidec
Quick Quote
C200-06500100A10101AB100
NIDEC C200-06500100A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series designed with air cooling. It operates on a supply voltage of 500Vac-575Vac, with dimensions of frame size 6 H15.39" x W8.27" x D8.94" (H291mm x W210mm x D227mm), and offers a degree of protection rated at IP20 NEMA 1. The rated current is 12A under normal duty and 10A under heavy-duty conditions. It supports Modbus RTU communication protocol over a 3-phase input network, with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. This model features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 additional digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) along with 1 x digital output (2A / 240Vac; source; relay contact type). It also includes 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 7.5kW under normal duty and 5.5kW under heavy-duty, with rated power of 10HP (normal duty) and 7.5HP / 7-1/2HP (heavy-duty).
Nidec
Quick Quote
C200-06400420A10101AB100
NIDEC C200-06400420A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series, designed with air cooling. It operates on a supply voltage of 380Vac-480Vac (400Vac / 415Vac) and has dimensions of frame size 6 H15.39" x W8.27" x D8.94" (H291mm x W210mm x D227mm), with a degree of protection rated at IP20 NEMA 1. The rated current is 48A for Normal duty and 42A for Heavy-duty. It supports Modbus RTU communication protocol over a 3-phase input network, with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation ranges from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 x digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) plus 1 x digital output (2A / 240Vac; source; relay contact type). The analog inputs include 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 22kW for Normal duty and 18.5kW for Heavy-duty, with a rated power of 30HP for both Normal and Heavy-duty applications.
Nidec
Quick Quote
C200-06400350A10101AB100
NIDEC C200-06400350A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the C200 series, designed with air cooling. It operates on a supply voltage of 380Vac-480Vac, including 400Vac and 415Vac, within a frame size of 6 measuring H15.39" x W8.27" x D8.94" (H291mm x W210mm x D227mm). This model offers a degree of protection rated at IP20 NEMA 1 and supports a rated current of 38A under normal duty and 35A under heavy-duty conditions. It utilizes the Modbus RTU communication protocol over a 3-phase input network, with a supply input frequency range of 45-66 Hz and an output frequency range of 0-550 Hz. The ambient air temperature for operation spans from -20°C to +60°C. It features 1 x analog output (10Vdc; source; single-ended), 5 x digital inputs (0-24Vdc; PNP/NPN) plus 1 additional digital input (0-24Vdc), and 1 x digital output (50mA / 0-24Vdc; source; PWM) along with 1 x digital output (2A / 240Vac; source; relay contact type). The analog inputs include 1 x analog input (0-20mA / 4-20mA / 0-10Vdc; single-ended; 11-bit conversion resolution) and 1 x analog input (0-10Vdc; single-ended; 11-bit conversion resolution). It is rated for an active power of 18.5kW under normal duty and 15kW under heavy-duty, equivalent to 25HP for both duty types.
Nidec
Quick Quote
HS72-07401000A10101AB100
NIDEC HS72-07401000A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the HS72 series designed for variable speed/frequency control with rated frequency outputs of 0-3000Hz in open loop and 0-1250Hz in closed loop applications. It features a built-in brake transistor and dual Safe Torque Off (STO) functionality suitable for high-speed applications, alongside air cooling for thermal management. The unit has dimensions of frame size 7, measuring H21.9" x W10.6" x D11" (H557mm x W270mm x D280mm), and supports Ethernet communication protocol. It operates with a rated current of 112A under normal duty and 100A under heavy-duty conditions, requiring a supply voltage of 380Vac-480Vac (specifically 400Vac / 415Vac). The drive is designed to function within an ambient air temperature range of -20°C to +40°C and has a degree of protection rated at IP20 NEMA 1 UL open. It accommodates a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency up to 3000 Hz. The device includes 2 x digital inputs (0-24Vdc, with terminal 8 configurable as a motor protection thermistor) and 3 x digital outputs (2 x 100mA / 0-24Vdc source and 1 x 2A / 240Vac source; relay contact type). It delivers a rated active power of 55kW under normal duty and 45kW under heavy-duty, with a rated power of 75HP for both duty types.
Nidec
Quick Quote
Items per page: