M000-11602380EU0100AN100
NIDEC M000-11602380EU0100AN100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter, part of the M000 series, designed for heavy-duty applications. It requires an external choke for air cooling and has dimensions of frame size 11E, measuring H46.9" x W12.2" x D12.3" (H1190mm x W310mm x D312mm). The rated current is 238A for heavy-duty operations, with a supply voltage range of 500Vac-690Vac (600Vac typical). It offers a degree of protection of IP20 NEMA 1 and operates on a network frequency of 50 Hz. The rated active power ranges from 90kW to 250kW, equivalent to 125HP to 400HP for heavy-duty tasks.
Nidec
Quick Quote
M000-11602380TU0100AB100
NIDEC M000-11602380TU0100AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter, part of the M000 series, designed with a built-in brake transistor, AC to DC twin rectifier, and air cooling. It features a frame size of 11T with dimensions of H46.9" x W12.2" x D12.3" (H1190mm x W310mm x D312mm). The rated current is 238A for heavy-duty applications, and it operates on a supply voltage of 500Vac-690Vac (600Vac) with a network frequency of 50 Hz. This model offers a degree of protection of IP20 NEMA 1 and supports rated active power ranging from 90kW to 250kW (heavy-duty) or rated power from 125HP to 400HP (heavy-duty).
Nidec
Quick Quote
M000-11602380EU0100AB100
NIDEC M000-11602380EU0100AB100 is a Variable Speed/Frequency Drive (VSD/VFD) from the M000 series designed for heavy-duty applications. It features a built-in brake transistor but requires an external choke and utilizes air cooling for temperature management. The unit has dimensions of frame size 11E, measuring H46.9" x W12.2" x D12.3" (H1190mm x W310mm x D312mm). It operates with a rated current of 238A and supports a supply voltage range of 500Vac-690Vac (600Vac), making it suitable for various industrial environments. The drive is rated for an active power range of 90kW-250kW and a power capacity of 125HP-400HP in heavy-duty operations. It is designed with a degree of protection of IP20 NEMA 1 and is compatible with a network frequency of 50 Hz on the supply input.
Nidec
Quick Quote
M000-11602630DU0100AB100
NIDEC M000-11602630DU0100AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter within the M000 series, designed with a built-in brake transistor and a built-in DC to AC inverter featuring air cooling. It has dimensions of frame size 11D, measuring H31.7" x W12.2" x D12.3" (H804mm x W310mm x D312mm). This model supports a rated current of 263A for heavy-duty applications, and operates on a supply voltage of 500Vac-690Vac (600Vac), with a network frequency supply input of 50 Hz. It offers a degree of protection of IP20 NEMA 1. The rated active power ranges from 90kW to 250kW for heavy-duty operations, equivalent to 125HP to 400HP.
Nidec
Quick Quote
M000-11602630EU0100AN100
NIDEC M000-11602630EU0100AN100 is a Variable Speed/Frequency Drive (VSD/VFD) also known as an inverter, part of the M000 series. This model requires an external choke for air cooling and comes in a frame size of 11E, with dimensions of H46.9" x W12.2" x D12.3" (H1190mm x W310mm x D312mm). It is designed to handle a rated current of 263A for heavy-duty applications. The supply voltage required for operation is between 500Vac and 690Vac, specifically optimized for 600Vac. It features a degree of protection rated at IP20 NEMA 1 and operates on a supply input network frequency of 50 Hz. The rated active power for this device ranges from 90kW to 250kW, equivalent to 125HP to 400HP for heavy-duty tasks.
Nidec
Quick Quote
M000-11602380TU0100AN100
NIDEC M000-11602380TU0100AN100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter within the M000 series, designed for AC to DC conversion with twin rectifier air cooling. It features a frame size of 11T, with dimensions of H46.9" x W12.2" x D12.3" (H1190mm x W310mm x D312mm). This model has a rated current of 238A for heavy-duty applications and operates on a supply voltage of 500Vac-690Vac, specifically optimized for 600Vac. It is equipped with a degree of protection rated at IP20 NEMA 1 and is designed to work with a network frequency of 50 Hz. The rated active power ranges from 90kW to 250kW for heavy-duty operations, corresponding to a rated power of 125HP to 400HP.
Nidec
Quick Quote
M000-11602380DU0100AN100
NIDEC M000-11602380DU0100AN100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter within the M000 series, designed with a built-in DC to AC inverter air cooling system. It features a frame size of 11D with dimensions of H31.7" x W12.2" x D12.3" (H804mm x W310mm x D312mm). This model has a rated current of 238A for heavy-duty applications and operates on a supply voltage of 500Vac-690Vac (600Vac), with a network frequency supply input of 50 Hz. It offers a degree of protection of IP20 NEMA 1. The rated active power ranges from 90kW to 250kW, and the rated power is between 125HP and 400HP for heavy-duty operations.
Nidec
Quick Quote
M000-11602380DU0100AB100
NIDEC M000-11602380DU0100AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter, part of the M000 series, designed with a built-in brake transistor and a built-in DC to AC inverter featuring air cooling. It has dimensions of frame size 11D, measuring H31.7" x W12.2" x D12.3" (H804mm x W310mm x D312mm). This model is rated for a heavy-duty current of 238A and operates on a supply voltage of 500Vac-690Vac (600Vac), with a network frequency supply input of 50 Hz. It offers a degree of protection of IP20 NEMA 1. The rated active power ranges from 90kW to 250kW, and the rated power is between 125HP and 400HP for heavy-duty applications.
Nidec
Quick Quote
M000-11602100TU0100AN100
NIDEC M000-11602100TU0100AN100 is a Variable Speed/Frequency Drive (VSD/VFD) also known as an inverter, belonging to the M000 series. This part is designed with AC to DC twin rectifier air cooling and comes in a frame size of 11T, with dimensions of H46.9" x W12.2" x D12.3" (H1190mm x W310mm x D312mm). It has a rated current of 210A for heavy-duty applications and operates on a supply voltage of 500Vac-690Vac (600Vac), with a network frequency supply input of 50 Hz. The degree of protection provided is IP20 NEMA 1. It supports a rated active power range of 90kW-250kW and a rated power of 125HP-400HP for heavy-duty operations.
Nidec
Quick Quote
M000-11602100TU0100AB100
NIDEC M000-11602100TU0100AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter, part of the M000 series, designed with a built-in brake transistor, AC to DC twin rectifier, and air cooling. It features a frame size of 11T with dimensions of H46.9" x W12.2" x D12.3" (H1190mm x W310mm x D312mm). This model has a rated current of 210A for heavy-duty applications, and it operates on a supply voltage of 500Vac-690Vac (600Vac) with a network frequency of 50 Hz. It offers a degree of protection of IP20 NEMA 1. The rated active power ranges from 90kW to 250kW, and the rated power is between 125HP and 400HP for heavy-duty operations.
Nidec
Quick Quote
M000-11602100EU0100AB100
NIDEC M000-11602100EU0100AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter within the M000 series. It features a built-in brake transistor and requires an external choke with air cooling for operation. The dimensions of this model are frame size 11E, measuring H46.9" x W12.2" x D12.3" (H1190mm x W310mm x D312mm). It has a rated current of 210A for heavy-duty applications and operates on a supply voltage of 500Vac-690Vac (600Vac), with a network frequency supply input of 50 Hz. The degree of protection provided is IP20 NEMA 1. This model is designed to deliver a rated active power ranging from 90kW to 250kW and a rated power of 125HP to 400HP for heavy-duty operations.
Nidec
Quick Quote
M000-11602100EU0100AN100
NIDEC M000-11602100EU0100AN100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter, part of the M000 series, designed for heavy-duty applications. It requires an external choke for air cooling and has dimensions of frame size 11E, measuring H46.9" x W12.2" x D12.3" (H1190mm x W310mm x D312mm). The rated current is 210A for heavy-duty operations, with a supply voltage range of 500Vac-690Vac (600Vac) and a network frequency supply input of 50 Hz. It offers a degree of protection of IP20 NEMA 1. The rated active power ranges from 90kW to 250kW, and the rated power is between 125HP and 400HP for heavy-duty tasks.
Nidec
Quick Quote
M000-11602100DU0100AB100
NIDEC M000-11602100DU0100AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M000 series designed with a built-in brake transistor and a built-in DC to AC inverter featuring air cooling. It has dimensions of frame size 11D, measuring H31.7" x W12.2" x D12.3" (H804mm x W310mm x D312mm). This model is rated for a heavy-duty current of 210A and operates on a supply voltage of 500Vac-690Vac (600Vac), with a network frequency supply input of 50 Hz. It offers a degree of protection of IP20 NEMA 1 and supports a rated active power range of 90kW-250kW (heavy-duty) or equivalently 125HP-400HP (heavy-duty).
Nidec
Quick Quote
M000-11602100DU0100AN100
NIDEC M000-11602100DU0100AN100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter within the M000 series, designed with a built-in DC to AC inverter featuring air cooling. It has dimensions of frame size 11D, measuring H31.7" x W12.2" x D12.3" (H804mm x W310mm x D312mm). This model is rated for a heavy-duty current of 210A and operates on a supply voltage of 500Vac-690Vac (600Vac), with a network frequency supply input of 50 Hz. It offers a degree of protection of IP20 NEMA 1. The rated active power ranges from 90kW to 250kW for heavy-duty applications, equivalent to 125HP to 400HP.
Nidec
Quick Quote
M000-11502850TU0100AN100
NIDEC M000-11502850TU0100AN100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter, part of the M000 series, designed for heavy-duty applications. It features an AC to DC twin rectifier air cooling design, with dimensions of frame size 11T, measuring H46.9" x W12.2" x D12.3" (H1190mm x W310mm x D312mm). The rated current is 285A, and it operates on a supply voltage of 500Vac-575Vac with a network frequency of 50 Hz. This model offers a degree of protection of IP20 NEMA 1 and supports rated active power ranging from 90kW to 250kW (125HP to 400HP) for heavy-duty operations.
Nidec
Quick Quote
M000-11502850TU0100AB100
NIDEC M000-11502850TU0100AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter, part of the M000 series, designed with a built-in brake transistor, AC to DC twin rectifier, and air cooling. It features a frame size of 11T with dimensions of H46.9" x W12.2" x D12.3" (H1190mm x W310mm x D312mm). This model has a rated current of 285A for heavy-duty applications, operates on a supply voltage of 500Vac-575Vac, and offers a degree of protection of IP20 NEMA 1. It is designed to work with a network frequency (supply input) of 50 Hz, has a rated active power range of 90kW-250kW, and a rated power of 125HP-400HP for heavy-duty operations.
Nidec
Quick Quote
M000-11502850EU0100AN100
NIDEC M000-11502850EU0100AN100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter, part of the M000 series, designed for heavy-duty applications. It requires an external choke for air cooling and comes in a frame size of 11E, with dimensions of H46.9" x W12.2" x D12.3" (H1190mm x W310mm x D312mm). This model has a rated current of 285A and operates on a supply voltage of 500Vac-575Vac. It is designed with a degree of protection of IP20 NEMA 1 and a network frequency (supply input) of 50 Hz. The rated active power ranges from 90kW to 250kW, equivalent to 125HP to 400HP for heavy-duty operations.
Nidec
Quick Quote
M000-11502850DU0100AN100
NIDEC M000-11502850DU0100AN100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter within the M000 series, designed with a built-in DC to AC inverter featuring air cooling. It has dimensions of frame size 11D, measuring H31.7" x W12.2" x D12.3" (H804mm x W310mm x D312mm). This model is rated for a heavy-duty current of 285A and operates on a supply voltage of 500Vac-575Vac. It is equipped with a degree of protection IP20 NEMA 1 and accepts a network frequency (supply input) of 50 Hz. The rated active power ranges from 90kW to 250kW for heavy-duty applications, corresponding to a rated power of 125HP to 400HP.
Nidec
Quick Quote
M000-11502850EU0100AB100
NIDEC M000-11502850EU0100AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M000 series designed with a built-in brake transistor, requiring an external choke and air cooling for operation. It features frame size 11E with dimensions of H46.9" x W12.2" x D12.3" (H1190mm x W310mm x D312mm). This model has a rated current of 285A for heavy-duty applications and operates on a supply voltage of 500Vac-575Vac. It is equipped with a degree of protection IP20 NEMA 1 and a network frequency (supply input) of 50 Hz. The rated active power ranges from 90kW to 250kW, and the rated power is between 125HP and 400HP for heavy-duty operations.
Nidec
Quick Quote
ATV61HD75Y
Schneider Electric ATV61HD75Y is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the Altivar 61 series designed for three-phase networks with a supply voltage range of 425-759Vac, including nominal voltages of 480Vac, 500Vac, 600Vac, and 690Vac. It features a built-in EMC filter of class C3, a built-in heatsink, and a coated version for enhanced chemical resistance, conforming to a reinforced version. The device offers a degree of protection of IP20 and UL type 1, with dimensions of H630mm x W320mm x D290mm. It supports a variety of control methods, including U/F ratio adjustment (2 points / 5 points / energy saving), sensorless flux vector control, and vector control without speed feedback, capable of delivering 120% of the nominal motor torque. The rated current is specified at 85A for 500Vac at 2.5kHz, 77A for 575Vac at 2.5kHz, 84A for 690Vac at 2.5kHz, and it can handle up to 102A max. current for 60 seconds. For connectivity, it includes Modbus and CANopen communication protocols, with 5 digital inputs, 1 additional digital input programmable as discrete or PTC input, another digital input for PWR safety, 1 digital output as C/O SPDT relay contact, another digital output as NO relay contact, and two analog inputs. The output frequency range is 0.1-500 Hz, and it also features 1 analog output. The device is designed for wall mounting and operates with a current consumption of 79A at 500Vac, 67A at 600Vac, and 82A at 690Vac, with rated active power of 75kW at 690Vac and 55kW at 500Vac, equivalent to 75HP.
Schneider Electric
Quick Quote