Filters
Variable Frequency Drives (VFD)
part#
description
manufacturer
M600-10202830E10101AB100
NIDEC M600-10202830E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M600 series designed with a built-in brake transistor, single Safe Torque Off (STO), and requires an external choke with air cooling for operation. It features dimensions of frame size 10E, measuring H39.7" x W12.21" x D11.42" (H1010mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 325A under normal duty and 283A under heavy-duty conditions. It is designed for a supply voltage of 200Vac-240Vac (220Vac / 230Vac) and can function within an ambient air temperature range of -20°C to +40°C. The device offers an IP20 NEMA 1 degree of protection and is suitable for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. It includes 2 x analog outputs, 3 x digital inputs, 3 x digital outputs plus 1 x relay contact type digital output, and 3 x analog inputs with varying specifications. The rated active power is 90kW for normal duty and 75kW for heavy-duty, corresponding to 125HP and 100HP, respectively.
Nidec
Quick Quote
M600-10402700E10101AB100
NIDEC M600-10402700E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M600 series designed with a built-in brake transistor, single Safe Torque Off (STO), and requires an external choke with air cooling for operation. It features dimensions of frame size 10E, measuring H39.7" x W12.21" x D11.42" (H1010mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 320A under normal duty and 270A under heavy-duty conditions. It is designed for a supply voltage of 380Vac-480Vac (specifically 400Vac / 415Vac) and can function within an ambient air temperature range of -20°C to +40°C. The device offers an IP20 NEMA 1 degree of protection and is suitable for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. It includes 2 analog outputs, 6 digital inputs, 4 digital outputs, and 3 analog inputs with varying specifications detailed in the description. The rated active power is 160kW for normal duty and 132kW for heavy-duty, corresponding to 250HP and 200HP, respectively.
Nidec
Quick Quote
M600-09601310E10101AB100
NIDEC M600-09601310E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M600 series designed for variable speed control with a built-in brake transistor, single Safe Torque Off (STO), and requires an external choke with air cooling for operation. It features frame size 9E with dimensions of H39.7" x W12.21" x D11.42" (H1010mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 155A under normal duty and 131A under heavy-duty conditions. It is designed for a supply voltage of 500Vac-690Vac (600Vac) and can operate in ambient air temperatures ranging from -20°C to +40°C. The drive offers an IP20 NEMA 1 degree of protection and is suitable for 3-phase input (3P) networks with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. It includes 2 x analog outputs, 3 x digital inputs, 3 x digital outputs plus 1 x digital output for relay contact type, and multiple analog inputs with varying specifications. The rated active power is 132kW for normal duty and 110kW for heavy-duty, corresponding to 175HP and 150HP, respectively.
Nidec
Quick Quote
M600-10203000E10101AN100
NIDEC M600-10203000E10101AN100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M600 series designed for variable speed control with a single Safe Torque Off (STO) and requires an external choke with air cooling. It features dimensions of frame size 10E, measuring H39.7" x W12.21" x D11.42" (H1010mm x W310mm x D290mm), and supports RS-485 Modbus RTU communication protocol. The drive operates with a rated current of 360A under normal duty and 300A under heavy-duty conditions, and it is designed for a supply voltage of 200Vac-240Vac (220Vac / 230Vac). It can function in ambient air temperatures ranging from -20°C to +40°C and has a degree of protection of IP20 NEMA 1. This model is suitable for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. It includes 2 x analog outputs, 3 x digital inputs, 3 x digital outputs plus 1 x relay contact type digital output, and multiple analog inputs with varying specifications. The rated active power is 110kW for normal duty and 90kW for heavy-duty, corresponding to 150HP and 125HP, respectively.
Nidec
Quick Quote
M600-09601040E10101AN100
NIDEC M600-09601040E10101AN100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M600 series designed for variable speed control with a single Safe Torque Off (STO) and requires an external choke with air cooling. It features dimensions of frame size 9E, measuring H39.7" x W12.21" x D11.42" (H1010mm x W310mm x D290mm), and operates on a RS-485 Modbus RTU communication protocol. The rated current is 125A under normal duty and 104A under heavy-duty conditions, with a supply voltage range of 500Vac-690Vac (600Vac). It is designed to operate within an ambient air temperature range of -20°C to +40°C and has a degree of protection of IP20 NEMA 1. This inverter supports a 3-phase input (3P) network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. It includes 2 x analog outputs (-10...+10Vdc; single-ended; source; 10-bit conversion resolution), 3 x digital inputs (0-24Vdc), 3 x digital outputs (100mA / 0-24Vdc; source), 1 x digital output (2A / 240Vac; relay contact type), and multiple analog inputs with varying specifications. The rated active power is 110kW under normal duty and 90kW under heavy-duty, corresponding to 150HP and 125HP, respectively.
Nidec
Quick Quote
M600-09501310E10101AB100
NIDEC M600-09501310E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M600 series designed with a built-in brake transistor, single Safe Torque Off (STO), and requires an external choke with air cooling for operation. It features dimensions of frame size 9E, measuring H39.7" x W12.21" x D11.42" (H1010mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 150A under normal duty and 131A under heavy-duty conditions. It is designed for a supply voltage of 500Vac-575Vac, can function within an ambient air temperature range of -20°C to +40°C, and offers a degree of protection rated at IP20 NEMA 1. The device accommodates a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. It includes 2 x analog outputs, 3 x digital inputs, 3 x digital outputs plus 1 x relay contact type digital output, and 3 x analog inputs with varying specifications for comprehensive control and feedback. The rated active power is 110kW for normal duty and 90kW for heavy-duty, corresponding to 150HP and 125HP, respectively.
Nidec
Quick Quote
M600-09601040E10101AB100
NIDEC M600-09601040E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M600 series designed with a built-in brake transistor, single Safe Torque Off (STO), and requires an external choke with air cooling for operation. It features dimensions of frame size 9E, measuring H39.7" x W12.21" x D11.42" (H1010mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 125A under normal duty and 104A under heavy-duty conditions. It is designed for a supply voltage of 500Vac-690Vac (600Vac) and can function within an ambient air temperature range of -20°C to +40°C. The device offers an IP20 NEMA 1 degree of protection and is compatible with a 3-phase input (3P) network, with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. It includes 2 x analog outputs, 3 x digital inputs, 3 x digital outputs, and 3 x analog inputs with varying specifications detailed in the description. The rated active power is 110kW for normal duty and 90kW for heavy-duty, corresponding to 150HP and 125HP, respectively.
Nidec
Quick Quote
M600-09601040A10101AB100
NIDEC M600-09601040A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M600 series designed with a built-in brake transistor and a single Safe Torque Off (STO) feature, utilizing air cooling. It has dimensions of frame size 9A, measuring H41.3" x W12.21" x D11.42" (H1049mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 125A under normal duty and 104A under heavy-duty conditions. It is designed for a supply voltage of 500Vac-690Vac (600Vac) and can function in ambient air temperatures ranging from -20°C to +40°C. The device offers an IP20 NEMA 1 degree of protection and is compatible with a 3-phase input (3P) network, with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. It features 2 x analog outputs, 3 x digital inputs, 3 x additional digital inputs, 3 x digital outputs, and 1 x digital output of a relay contact type, alongside multiple analog inputs with varying specifications. The rated active power is 110kW under normal duty and 90kW under heavy-duty, corresponding to 150HP and 125HP, respectively.
Nidec
Quick Quote
M600-09601310A10101AB100
NIDEC M600-09601310A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M600 series designed with a built-in brake transistor and a single Safe Torque Off (STO) feature, utilizing air cooling. It has dimensions of frame size 9A, measuring H41.3" x W12.21" x D11.42" (H1049mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 155A under normal duty and 131A under heavy-duty conditions. It is designed for a supply voltage of 500Vac-690Vac (600Vac) and can function in ambient air temperatures ranging from -20°C to +40°C. The device offers an IP20 NEMA 1 degree of protection and is compatible with a 3-phase input (3P) network, with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. It features 2 x analog outputs, 3 x digital inputs, 3 x additional digital inputs, 3 x digital outputs, and 1 x digital output of a relay contact type, alongside 3 x analog inputs with varying specifications. The rated active power is 132kW under normal duty and 110kW under heavy-duty, corresponding to 175HP and 150HP, respectively.
Nidec
Quick Quote
M600-09501310E10101AN100
NIDEC M600-09501310E10101AN100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M600 series designed for variable speed control with a single Safe Torque Off (STO) and requires an external choke and air cooling. It features dimensions of frame size 9E, measuring H39.7" x W12.21" x D11.42" (H1010mm x W310mm x D290mm), and operates with an RS-485 Modbus RTU communication protocol. The rated current is 150A under normal duty and 131A under heavy-duty conditions, with a supply voltage range of 500Vac-575Vac. It is designed to operate in ambient air temperatures ranging from -20°C to +40°C and has a degree of protection rated at IP20 NEMA 1. This inverter supports a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. It includes 2 x analog outputs, 3 x digital inputs, 3 x additional digital inputs, 3 x digital outputs plus 1 x digital output with relay contact type, and 3 x analog inputs with varying specifications. The rated active power is 110kW under normal duty and 90kW under heavy-duty, equivalent to 150HP and 125HP, respectively.
Nidec
Quick Quote
M600-09501310A10101AB100
NIDEC M600-09501310A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M600 series designed with a built-in brake transistor and a single Safe Torque Off (STO) feature, utilizing air cooling. It has dimensions of frame size 9A, measuring H41.3" x W12.21" x D11.42" (H1049mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 150A under normal duty and 131A under heavy-duty conditions. It requires a supply voltage of 500Vac-575Vac and is designed to function within an ambient air temperature range of -20°C to +40°C. The device offers an IP20 NEMA 1 degree of protection and is compatible with a 3-phase input network, supporting a network frequency of 45-66 Hz (supply input) and output frequency range of 0-550 Hz. It features 2 x analog outputs, 3 x digital inputs, 3 x digital outputs, and multiple analog inputs with varying specifications, including differential and single-ended configurations with 10-bit and 11-bit conversion resolutions. The rated active power is 110kW for normal duty and 90kW for heavy-duty, corresponding to 150HP and 125HP, respectively.
Nidec
Quick Quote
M600-09501040E10101AB100
NIDEC M600-09501040E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M600 series designed with a built-in brake transistor, single Safe Torque Off (STO), and requires an external choke with air cooling for operation. It features dimensions of frame size 9E, measuring H39.7" x W12.21" x D11.42" (H1010mm x W310mm x D290mm), and supports RS-485 Modbus RTU communication protocol. The rated current is 125A under normal duty and 104A under heavy-duty conditions, with a supply voltage range of 500Vac-575Vac. It operates within an ambient air temperature range of -20°C to +40°C and has a degree of protection rated at IP20 NEMA 1. This part is designed for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. It includes 2 x analog outputs, 3 x digital inputs, 3 x digital outputs, and 3 x analog inputs with varying specifications detailed in the description. The rated active power is 110kW for normal duty and 75kW for heavy-duty, corresponding to 125HP and 100HP, respectively.
Nidec
Quick Quote
M600-09501040A10101AB100
NIDEC M600-09501040A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M600 series designed with a built-in brake transistor and a single Safe Torque Off (STO) feature, utilizing air cooling. It has dimensions of frame size 9A, measuring H41.3" x W12.21" x D11.42" (H1049mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 125A under normal duty and 104A under heavy-duty conditions. It requires a supply voltage of 500Vac-575Vac and is designed to function within an ambient air temperature range of -20°C to +40°C. The device offers an IP20 NEMA 1 degree of protection and is compatible with a 3-phase input network, supporting a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. It features 2 x analog outputs, 3 x digital inputs, 3 x digital outputs, and multiple analog inputs with varying specifications, including differential and single-ended configurations with 10-bit and 11-bit conversion resolutions. The rated active power is 110kW for normal duty and 75kW for heavy-duty, corresponding to 125HP and 100HP, respectively.
Nidec
Quick Quote
M600-09501040E10101AN100
NIDEC M600-09501040E10101AN100 is a Variable Speed/Frequency Drive (VSD/VFD) from the M600 series designed for variable speed control with a single Safe Torque Off (STO), requiring an external choke and air cooling. It features dimensions of frame size 9E, measuring H39.7" x W12.21" x D11.42" (H1010mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 125A under normal duty and 104A under heavy-duty conditions. It is designed for a supply voltage range of 500Vac-575Vac and can operate in ambient air temperatures ranging from -20°C to +40°C. The device offers an IP20 NEMA 1 degree of protection and is suitable for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. It includes 2 analog outputs, 6 digital inputs, 4 digital outputs, and 3 analog inputs with varying specifications for conversion resolution and type. The rated active power is 110kW for normal duty and 75kW for heavy-duty, corresponding to 125HP and 100HP, respectively.
Nidec
Quick Quote
M600-09402240E10101AN100
NIDEC M600-09402240E10101AN100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M600 series designed with a single Safe Torque Off (STO), requiring an external choke and air cooling. It features dimensions of frame size 9E, measuring H39.7" x W12.21" x D11.42" (H1010mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 266A under normal duty and 224A under heavy-duty conditions. It is designed for a supply voltage of 380Vac-480Vac (400Vac / 415Vac) and can function within an ambient air temperature range of -20°C to +40°C. The device offers an IP20 NEMA 1 degree of protection and is compatible with a 3-phase input (3P) network, supporting a supply input frequency of 45-66 Hz and an output frequency of 0-550 Hz. It includes 2 x analog outputs, 3 x digital inputs, 3 x digital outputs plus 1 x digital output of a relay contact type, and 3 x analog inputs with varying specifications. The rated active power is 132kW for normal duty and 110kW for heavy-duty, corresponding to 200HP and 150HP, respectively.
Nidec
Quick Quote
M600-09402240E10101AB100
NIDEC M600-09402240E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M600 series designed with a built-in brake transistor, single Safe Torque Off (STO), and requires an external choke with air cooling for operation. It features dimensions of frame size 9E, measuring H39.7" x W12.21" x D11.42" (H1010mm x W310mm x D290mm), and utilizes the RS-485 Modbus RTU communication protocol. The drive operates with a rated current of 266A under normal duty and 224A under heavy-duty conditions, supported by a supply voltage range of 380Vac-480Vac (specifically 400Vac / 415Vac). It is designed to function within an ambient air temperature range of -20°C to +40°C and offers a degree of protection rated at IP20 NEMA 1. This VSD/VFD is suitable for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. It includes 2 analog outputs, 6 digital inputs, 4 digital outputs, and 3 analog inputs with varying specifications for comprehensive control and feedback. The rated active power is 132kW under normal duty and 110kW under heavy-duty, equivalent to 200HP and 150HP respectively.
Nidec
Quick Quote
M600-09402000E10101AN100
NIDEC M600-09402000E10101AN100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M600 series designed for variable speed control with a single Safe Torque Off (STO) and requires an external choke and air cooling. It features dimensions of frame size 9E, measuring H39.7" x W12.21" x D11.42" (H1010mm x W310mm x D290mm), and operates on a RS-485 Modbus RTU communication protocol. The rated current is 221A under normal duty and 200A under heavy-duty conditions, with a supply voltage range of 380Vac-480Vac (specifically 400Vac / 415Vac). It is designed to operate within an ambient air temperature range of -20°C to +40°C and has a degree of protection rated at IP20 NEMA 1. This VSD/VFD supports a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. It includes 2 x analog outputs, 3 x digital inputs, 3 x digital outputs plus 1 x digital output for relay contact type, and 3 x analog inputs with varying specifications. The rated active power is 110kW under normal duty and 90kW under heavy-duty, equivalent to 150HP for both duty types.
Nidec
Quick Quote
M600-09402240A10101AB100
NIDEC M600-09402240A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M600 series designed with a built-in brake transistor and a single Safe Torque Off (STO) feature, utilizing air cooling. It has dimensions of frame size 9A, measuring H41.3" x W12.21" x D11.42" (H1049mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 266A under normal duty and 224A under heavy-duty conditions. It is designed for a supply voltage of 380Vac-480Vac (400Vac / 415Vac) and can function within an ambient air temperature range of -20°C to +40°C. The device offers an IP20 NEMA 1 degree of protection and is suitable for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. It features 2 x analog outputs, 3 x digital inputs, 3 x digital outputs plus 1 x relay contact type digital output, and 3 x analog inputs with varying specifications for comprehensive control and feedback. The rated active power is 132kW under normal duty and 110kW under heavy-duty, equivalent to 200HP and 150HP respectively.
Nidec
Quick Quote
M600-09202190E10101AB100
NIDEC M600-09202190E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M600 series designed with a built-in brake transistor, single Safe Torque Off (STO), and requires an external choke with air cooling for operation. It features dimensions of frame size 9E, measuring H39.7" x W12.21" x D11.42" (H1010mm x W310mm x D290mm), and utilizes the RS-485 Modbus RTU communication protocol. The rated current is 266A under normal duty and 219A under heavy-duty conditions, with a supply voltage range of 200Vac-240Vac (220Vac / 230Vac). It operates within an ambient air temperature range of -20°C to +40°C and has a degree of protection rated at IP20 NEMA 1. This part is designed for a 3-phase input (3P) network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. It includes 2 x analog outputs, 3 x digital inputs, 3 x digital outputs, and 3 x analog inputs with varying specifications detailed in the description. The rated active power is 75kW under normal duty and 55kW under heavy-duty, corresponding to 100HP and 75HP, respectively.
Nidec
Quick Quote
ATV61HD75Y
Schneider Electric ATV61HD75Y is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the Altivar 61 series designed for three-phase networks with a supply voltage range of 425-759Vac, including nominal voltages of 480Vac, 500Vac, 600Vac, and 690Vac. It features a built-in EMC filter of class C3, a built-in heatsink, and a coated version for enhanced chemical resistance, conforming to a reinforced version. The device offers a degree of protection of IP20 and UL type 1, with dimensions of H630mm x W320mm x D290mm. It supports a variety of control methods, including U/F ratio adjustment (2 points / 5 points / energy saving), sensorless flux vector control, and vector control without speed feedback, capable of delivering 120% of the nominal motor torque. The rated current is specified at 85A for 500Vac at 2.5kHz, 77A for 575Vac at 2.5kHz, 84A for 690Vac at 2.5kHz, and it can handle up to 102A max. current for 60 seconds. For connectivity, it includes Modbus and CANopen communication protocols, with 5 digital inputs, 1 additional digital input programmable as discrete or PTC input, another digital input for PWR safety, 1 digital output as C/O SPDT relay contact, another digital output as NO relay contact, and two analog inputs. The output frequency range is 0.1-500 Hz, and it also features 1 analog output. The device is designed for wall mounting and operates with a current consumption of 79A at 500Vac, 67A at 600Vac, and 82A at 690Vac, with rated active power of 75kW at 690Vac and 55kW at 500Vac, equivalent to 75HP.
Schneider Electric
Quick Quote
Items per page: