Filters
Variable Frequency Drives (VFD)
part#
description
manufacturer
M701-03400062A10101AB100
NIDEC M701-03400062A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor and a single Safe Torque Off (STO) feature, utilizing air cooling. It has dimensions of frame size 3, measuring H14.37" x W3.27" x D7.87" (H365mm x W83mm x D200mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 7.7A under normal duty and 6.2A under heavy-duty conditions. It is designed for a supply voltage of 380Vac-480Vac (400Vac / 415Vac) and can function in ambient air temperatures ranging from -20°C to +40°C. The device offers an IP20 NEMA 1 UL open degree of protection and is compatible with a 3-phase input network, supporting a supply input frequency of 45-66 Hz and an output frequency of 0-599 Hz. It features 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), and 4 digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type). Additionally, it includes 1 analog input (0-20mA / 4-20mA / -10...+10Vdc; differential; 11-bit conversion resolution) and 2 analog inputs (0-20mA / 4-20mA / -10...+10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 3kW for normal duty and 2.2kW for heavy-duty, with corresponding rated power of 5HP and 3HP, respectively.
Nidec
Quick Quote
M701-03400045A10101AB100
NIDEC M701-03400045A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series, designed with a built-in brake transistor and a single Safe Torque Off (STO) feature, utilizing air cooling. It has dimensions of frame size 3, measuring H14.37" x W3.27" x D7.87" (H365mm x W83mm x D200mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 6.2A under normal duty and 4.5A under heavy-duty conditions. It is designed for a supply voltage of 380Vac-480Vac (400Vac / 415Vac) and can function in ambient air temperatures ranging from -20°C to +40°C. The device offers an IP20 NEMA 1 UL open degree of protection and is compatible with a 3-phase input network, supporting a supply input frequency of 45-66 Hz and an output frequency of 0-599 Hz. It features 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), 4 digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type), and 3 analog inputs (0-20mA / 4-20mA / -10...+10Vdc; differential and single-ended; 11-bit conversion resolution). The rated active power is 2.2kW under normal duty and 1.5kW under heavy-duty, with a rated power of 3HP (normal duty) and 2HP (heavy-duty).
Nidec
Quick Quote
M701-03400031A10101AB100
NIDEC M701-03400031A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor and a single Safe Torque Off (STO) feature, utilizing air cooling for temperature management. It has dimensions of frame size 3, measuring H14.37" x W3.27" x D7.87" (H365mm x W83mm x D200mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 4.5A under normal duty and 3.1A under heavy-duty conditions. It is designed for a supply voltage of 380Vac-480Vac (400Vac / 415Vac) and can function within an ambient air temperature range of -20°C to +40°C. The device offers an IP20 NEMA 1 UL open degree of protection and is compatible with a 3-phase input network, supporting a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It features 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), and 4 digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type), along with 3 analog inputs (1 x differential and 2 x single-ended; 11-bit conversion resolution). The rated active power is 1.5kW for normal duty and 1.1kW for heavy-duty, corresponding to a rated power of 2HP under normal duty and 1.5HP / 1-1/2HP under heavy-duty conditions.
Nidec
Quick Quote
M701-03400025A10101AB100
NIDEC M701-03400025A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor and a single Safe Torque Off (STO) feature, utilizing air cooling. It has dimensions of frame size 3, measuring H14.37" x W3.27" x D7.87" (H365mm x W83mm x D200mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 3.4A under normal duty and 2.5A under heavy-duty conditions. It is designed for a supply voltage of 380Vac-480Vac (400Vac / 415Vac) and can function within an ambient air temperature range of -20°C to +40°C. The device offers an IP20 NEMA 1 UL open degree of protection and is compatible with a 3-phase input network, supporting a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It features 2 x analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 x digital inputs (0-24Vdc), 4 x digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type), and 3 x analog inputs (0-20mA / 4-20mA / -10...+10Vdc; differential and single-ended; 11-bit conversion resolution). The rated active power is 1.1kW for normal duty and 0.75kW for heavy-duty, with rated power of 1.5HP / 1-1/2HP for normal duty and 1HP for heavy-duty.
Nidec
Quick Quote
M701-03200106A10101AB100
NIDEC M701-03200106A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor and a single Safe Torque Off (STO) feature, utilizing air cooling. It has dimensions of frame size 3, measuring H14.37" x W3.27" x D7.87" (H365mm x W83mm x D200mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 12.7A under normal duty and 10.6A under heavy-duty conditions. It is designed for a supply voltage of 200Vac-240Vac (220Vac / 230Vac) and can function within an ambient air temperature range of -20°C to +40°C. The device offers an IP20 NEMA 1 UL open degree of protection and is compatible with a 3-phase input network, supporting a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It features 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), and 4 digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type), along with 3 analog inputs (0-20mA / 4-20mA / -10...+10Vdc; differential and single-ended; 11-bit conversion resolution). The rated active power is 3kW for normal duty and 2.2kW for heavy-duty, with a rated power of 3HP for both conditions.
Nidec
Quick Quote
M701-03200080A10101AB100
NIDEC M701-03200080A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor, single Safe Torque Off (STO), and air cooling. It features dimensions of frame size 3, measuring H14.37" x W3.27" x D7.87" (H365mm x W83mm x D200mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 11A under normal duty and 8A under heavy-duty conditions. It requires a supply voltage of 200Vac-240Vac (220Vac / 230Vac) and is designed to function within an ambient air temperature range of -20°C to +40°C. The device offers an IP20 NEMA 1 UL open degree of protection and is compatible with a 3-phase input network, supporting a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 x analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 3 x digital inputs (0-24Vdc), 3 x digital outputs (0-24Vdc; source), 1 x digital output (2A / 240Vac; source; relay contact type), and analog inputs comprising 1 x differential (0-20mA / 4-20mA / -10...+10Vdc; 11-bit conversion resolution) and 2 x single-ended (0-20mA / 4-20mA / -10...+10Vdc; 11-bit conversion resolution). The rated active power is 2.2kW under normal duty and 1.5kW under heavy-duty, with corresponding rated power of 3HP and 2HP, respectively.
Nidec
Quick Quote
M701-03200066A10101AB100
NIDEC M701-03200066A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor and a single Safe Torque Off (STO) feature, utilizing air cooling. It has dimensions of frame size 3, measuring H14.37" x W3.27" x D7.87" (H365mm x W83mm x D200mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 8A under normal duty and 6.6A under heavy-duty conditions. It requires a supply voltage of 200Vac-240Vac (220Vac / 230Vac) and is designed to function within an ambient air temperature range of -20°C to +40°C. The device offers an IP20 NEMA 1 UL open degree of protection and is compatible with a 3-phase input network, supporting a network frequency of 45-66 Hz (supply input) and output frequency range of 0-599 Hz. It features 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), 4 digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type), and 3 analog inputs (1 x differential and 2 x single-ended; 0-20mA / 4-20mA / -10...+10Vdc; 11-bit conversion resolution). The rated active power is 1.5kW for normal duty and 1.1kW for heavy-duty, with corresponding rated power of 2HP and 1.5HP / 1-1/2HP, respectively.
Nidec
Quick Quote
M701-03200050A10101AB100
NIDEC M701-03200050A10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series, designed with a built-in brake transistor and a single Safe Torque Off (STO) feature for air cooling. It has dimensions of frame size 3, measuring H14.37" x W3.27" x D7.87" (H365mm x W83mm x D200mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 6.6A under normal duty and 5A under heavy-duty conditions. It is designed for a supply voltage of 200Vac-240Vac (220Vac / 230Vac) and can function within an ambient air temperature range of -20°C to +40°C. The device offers an IP20 NEMA 1 UL open degree of protection and is compatible with a 3-phase input network, supporting a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It features 2 x analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 3 x digital inputs (0-24Vdc), 3 x digital outputs (0-24Vdc; source) plus 1 x digital output (2A / 240Vac; source; relay contact type), and analog inputs including 1 x differential (0-20mA / 4-20mA / -10...+10Vdc; 11-bit conversion resolution) and 2 x single-ended (0-20mA / 4-20mA / -10...+10Vdc; 11-bit conversion resolution). The rated active power is 1.1kW for normal duty and 0.75kW for heavy-duty, with rated power of 1.5HP / 1-1/2HP for normal duty and 1HP for heavy-duty.
Nidec
Quick Quote
M600-11602630E10101AN100
NIDEC M600-11602630E10101AN100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M600 series designed with a single Safe Torque Off (STO) and requires an external choke and air cooling for operation. It features dimensions of frame size 11E, measuring H46.9" x W12.2" x D48.9" (H1190mm x W310mm x D312mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 305A under normal duty and 263A under heavy-duty conditions. It is designed for a supply voltage of 500Vac-690Vac (600Vac) and can function within an ambient air temperature range of -20°C to +40°C. The degree of protection offered is IP20 NEMA 1, suitable for 3-phase input (3P) networks with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. It includes 2 x analog outputs, 3 x digital inputs, 3 x digital outputs, and 1 x digital output of varying specifications, alongside 3 x analog inputs with detailed conversion resolutions. The rated active power is 315kW for normal duty and 250kW for heavy-duty, equivalent to 400HP and 300HP respectively.
Nidec
Quick Quote
M600-11602630E10101AB100
NIDEC M600-11602630E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M600 series designed with a built-in brake transistor, single Safe Torque Off (STO), and requires an external choke with air cooling for operation. It features dimensions of frame size 11E, measuring H46.9" x W12.2" x D48.9" (H1190mm x W310mm x D312mm), and operates on a RS-485 Modbus RTU communication protocol. The rated current is 305A under normal duty and 263A under heavy-duty conditions, with a supply voltage range of 500Vac-690Vac (600Vac). It is designed to operate within an ambient air temperature range of -20°C to +40°C and has a degree of protection rated at IP20 NEMA 1. This VSD/VFD supports a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. It includes 2 x analog outputs, 3 x digital inputs, 3 x digital outputs, and multiple analog inputs with varying specifications. The rated active power is 315kW for normal duty and 250kW for heavy-duty, equivalent to 400HP and 300HP respectively.
Nidec
Quick Quote
M600-11602380E10101AN100
NIDEC M600-11602380E10101AN100 is a Variable Speed/Frequency Drive (VSD/VFD) from the M600 series designed for variable speed control with a single Safe Torque Off (STO) feature, requiring an external choke and air cooling. It has dimensions of frame size 11E, measuring H46.9" x W12.2" x D48.9" (H1190mm x W310mm x D312mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 275A under normal duty and 238A under heavy-duty conditions. It is designed for a supply voltage of 500Vac-690Vac (600Vac) and can function within an ambient air temperature range of -20°C to +40°C. The drive offers an IP20 NEMA 1 degree of protection and is suitable for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. It features 2 analog outputs, 6 digital inputs, 4 digital outputs, and 3 analog inputs with varying specifications for comprehensive control and feedback. The rated active power is 250kW for normal duty and 200kW for heavy-duty applications, equivalent to 300HP and 250HP, respectively.
Nidec
Quick Quote
M600-11602380E10101AB100
NIDEC M600-11602380E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M600 series designed with a built-in brake transistor, single Safe Torque Off (STO), and requires an external choke with air cooling for operation. It features dimensions of frame size 11E, measuring H46.9" x W12.2" x D48.9" (H1190mm x W310mm x D312mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 275A under normal duty and 238A under heavy-duty conditions. It is designed for a supply voltage of 500Vac-690Vac (600Vac) and can function within an ambient air temperature range of -20°C to +40°C. The device offers an IP20 NEMA 1 degree of protection and is suitable for a 3-phase input (3P) network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. It includes 2 x analog outputs, 3 x digital inputs, 3 x digital outputs plus 1 x digital output of relay contact type, and 3 x analog inputs with varying specifications. The rated active power is 250kW under normal duty and 200kW under heavy-duty, corresponding to 300HP and 250HP, respectively.
Nidec
Quick Quote
M600-11602100E10101AN100
NIDEC M600-11602100E10101AN100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M600 series designed with a single Safe Torque Off (STO) and requires an external choke for air cooling. It features dimensions of frame size 11E, measuring H46.9" x W12.2" x D48.9" (H1190mm x W310mm x D312mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 225A under normal duty and 210A under heavy-duty conditions. It is designed for a supply voltage of 500Vac-690Vac (600Vac) and can function in ambient air temperatures ranging from -20°C to +40°C. The device offers an IP20 NEMA 1 degree of protection and is compatible with a 3-phase input (3P) network, with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. It includes 2 x analog outputs, 3 x digital inputs, 3 x digital outputs plus 1 x digital output for relay contact type, and 3 x analog inputs with varying specifications for comprehensive control and feedback. The rated active power is 200kW for normal duty and 185kW for heavy-duty operations, with a rated power of 250HP for both conditions.
Nidec
Quick Quote
M600-11502850E10101AB100
NIDEC M600-11502850E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M600 series designed with a built-in brake transistor, single Safe Torque Off (STO), and requires an external choke with air cooling for operation. It features dimensions of frame size 11E, measuring H46.9" x W12.2" x D48.9" (H1190mm x W310mm x D312mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 315A under normal duty and 285A under heavy-duty conditions. It is designed for a supply voltage range of 500Vac-575Vac and can operate in ambient air temperatures ranging from -20°C to +40°C. The device offers an IP20 NEMA 1 degree of protection and is suitable for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. It includes 2 x analog outputs, 3 x digital inputs, 3 x additional digital inputs, 3 x digital outputs, and 1 x digital output with relay contact type, alongside 3 x analog inputs with varying specifications. The rated active power is 250kW for normal duty and 225kW for heavy-duty, corresponding to 350HP and 300HP, respectively.
Nidec
Quick Quote
M600-11602100E10101AB100
NIDEC M600-11602100E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M600 series designed with a built-in brake transistor, single Safe Torque Off (STO), and requires an external choke with air cooling for operation. It features dimensions of frame size 11E, measuring H46.9" x W12.2" x D48.9" (H1190mm x W310mm x D312mm), and utilizes the RS-485 Modbus RTU communication protocol. The drive has a rated current of 225A under normal duty and 210A under heavy-duty conditions, with a supply voltage range of 500Vac-690Vac (600Vac). It operates within an ambient air temperature range of -20°C to +40°C and offers a degree of protection rated at IP20 NEMA 1. This model supports a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. It includes 2 analog outputs, 6 digital inputs, 4 digital outputs, and 3 analog inputs with varying specifications detailed in the description. The rated active power is 200kW for normal duty and 185kW for heavy-duty, with a rated power of 250HP for both operational modes.
Nidec
Quick Quote
M600-11502850E10101AN100
NIDEC M600-11502850E10101AN100 is a Variable Speed/Frequency Drive (VSD/VFD) from the M600 series designed for variable speed control with a single Safe Torque Off (STO) and requires an external choke for air cooling. It features dimensions of frame size 11E, measuring H46.9" x W12.2" x D48.9" (H1190mm x W310mm x D312mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 315A under normal duty and 285A under heavy-duty conditions. It is designed for a supply voltage range of 500Vac-575Vac and can function in ambient air temperatures ranging from -20°C to +40°C. The drive offers an IP20 NEMA 1 degree of protection and is compatible with a 3-phase input network, supporting a supply input frequency of 45-66 Hz and an output frequency range of 0-550 Hz. It includes 2 x analog outputs, 3 x digital inputs, 3 x digital outputs, and multiple analog inputs with varying specifications for comprehensive control and feedback. The rated active power is 250kW for normal duty and 225kW for heavy-duty applications, corresponding to 350HP and 300HP, respectively.
Nidec
Quick Quote
M600-11502540E10101AB100
NIDEC M600-11502540E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M600 series designed with a built-in brake transistor, single Safe Torque Off (STO), and requires an external choke with air cooling for operation. It features dimensions of frame size 11E, measuring H46.9" x W12.2" x D48.9" (H1190mm x W310mm x D312mm), and utilizes the RS-485 Modbus RTU communication protocol. The rated current is 288A for Normal duty and 254A for Heavy-duty, with a supply voltage range of 500Vac-575Vac. It operates within an ambient air temperature range of -20°C to +40°C and has a degree of protection rated at IP20 NEMA 1. This part is designed for a 3-phase input network with a frequency range of 45-66 Hz for supply input and 0-550 Hz for output. It includes 2 x analog outputs, 3 x digital inputs, 3 x additional digital inputs, 3 x digital outputs, and 1 x digital output of relay contact type, alongside 3 x analog inputs with varying specifications. The rated active power is 225kW for Normal duty and 185kW for Heavy-duty, corresponding to 300HP and 250HP, respectively.
Nidec
Quick Quote
M600-11502540E10101AN100
NIDEC M600-11502540E10101AN100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M600 series designed for variable speed control with a single Safe Torque Off (STO) and requires an external choke for air cooling. It features dimensions of frame size 11E, measuring H46.9" x W12.2" x D48.9" (H1190mm x W310mm x D312mm), and operates with a communication protocol of RS-485 Modbus RTU. The rated current is 288A under normal duty and 254A under heavy-duty conditions, with a supply voltage range of 500Vac-575Vac. It is designed to operate within an ambient air temperature range of -20°C to +40°C and has a degree of protection rated at IP20 NEMA 1. This inverter supports a 3-phase input network with a frequency range of 45-66 Hz for supply input and 0-550 Hz for output. It includes 2 x analog outputs, 3 x digital inputs, 3 x digital outputs, and multiple analog inputs with varying specifications. The rated active power is 225kW for normal duty and 185kW for heavy-duty, corresponding to 300HP and 250HP, respectively.
Nidec
Quick Quote
M600-11502000E10101AN100
NIDEC M600-11502000E10101AN100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M600 series designed for variable speed control with a single Safe Torque Off (STO) and requires an external choke with air cooling. It features dimensions of frame size 11E, measuring H46.9" x W12.2" x D48.9" (H1190mm x W310mm x D312mm), and operates on a RS-485 Modbus RTU communication protocol. The rated current is 248A for Normal duty and 200A for Heavy-duty, with a supply voltage range of 500Vac-575Vac. It is designed to operate in ambient air temperatures ranging from -20°C to +40°C and has a degree of protection of IP20 NEMA 1. This inverter supports a 3-phase input network with a frequency range of 45-66 Hz for supply input and 0-550 Hz for output. It includes 2 x analog outputs, 3 x digital inputs, 3 x digital outputs plus 1 x relay contact type digital output, and 3 x analog inputs with varying specifications for comprehensive control. The rated active power is 175kW for Normal duty and 150kW for Heavy-duty, equivalent to 250HP and 200HP respectively.
Nidec
Quick Quote
ATV61HD75Y
Schneider Electric ATV61HD75Y is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the Altivar 61 series designed for three-phase networks with a supply voltage range of 425-759Vac, including nominal voltages of 480Vac, 500Vac, 600Vac, and 690Vac. It features a built-in EMC filter of class C3, a built-in heatsink, and a coated version for enhanced chemical resistance, conforming to a reinforced version. The device offers a degree of protection of IP20 and UL type 1, with dimensions of H630mm x W320mm x D290mm. It supports a variety of control methods, including U/F ratio adjustment (2 points / 5 points / energy saving), sensorless flux vector control, and vector control without speed feedback, capable of delivering 120% of the nominal motor torque. The rated current is specified at 85A for 500Vac at 2.5kHz, 77A for 575Vac at 2.5kHz, 84A for 690Vac at 2.5kHz, and it can handle up to 102A max. current for 60 seconds. For connectivity, it includes Modbus and CANopen communication protocols, with 5 digital inputs, 1 additional digital input programmable as discrete or PTC input, another digital input for PWR safety, 1 digital output as C/O SPDT relay contact, another digital output as NO relay contact, and two analog inputs. The output frequency range is 0.1-500 Hz, and it also features 1 analog output. The device is designed for wall mounting and operates with a current consumption of 79A at 500Vac, 67A at 600Vac, and 82A at 690Vac, with rated active power of 75kW at 690Vac and 55kW at 500Vac, equivalent to 75HP.
Schneider Electric
Quick Quote
Items per page: