Filters
Variable Frequency Drives (VFD)
part#
description
manufacturer
M701-11602630E10101AB100
NIDEC M701-11602630E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor, single Safe Torque Off (STO), and requires an external choke with air cooling for operation. It features dimensions of frame size 11E, measuring H46.9" x W12.2" x D48.9" (H1190mm x W310mm x D312mm), and utilizes the RS-485 Modbus RTU communication protocol. The drive operates with a rated current of 305A under normal duty and 263A under heavy-duty conditions, supported by a supply voltage range of 500Vac-690Vac (600Vac). It is designed to function within an ambient air temperature range of -20°C to +40°C and offers a degree of protection rated at IP20 NEMA 1 UL open. This VSD/VFD is compatible with a 3-phase input network, supporting a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), and 4 digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type), alongside 3 analog inputs (0-20mA / 4-20mA / -10...+10Vdc; with different conversion resolutions and input types). The rated active power is 315kW under normal duty and 250kW under heavy-duty, equivalent to 400HP and 300HP respectively.
Nidec
Quick Quote
M701-11602100E10101AN100
NIDEC M701-11602100E10101AN100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed for variable speed control with a single Safe Torque Off (STO) and requires an external choke for air cooling. It features dimensions of frame size 11E, measuring H46.9" x W12.2" x D48.9" (H1190mm x W310mm x D312mm), and operates with a communication protocol of RS-485 Modbus RTU. The rated current is 225A under normal duty and 210A under heavy-duty conditions, with a supply voltage range of 500Vac-690Vac (600Vac). It is designed to operate within an ambient air temperature range of -20°C to +40°C and has a degree of protection rated at IP20 NEMA 1 UL open. This inverter supports a 3-phase input (3P) network with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 x analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 3 x digital inputs (0-24Vdc), 3 x digital outputs (0-24Vdc; source) plus 1 x digital output (2A / 240Vac; source; relay contact type), and analog inputs comprising 1 x differential (0-20mA / 4-20mA / -10...+10Vdc; 11-bit conversion resolution) and 2 x single-ended (0-20mA / 4-20mA / -10...+10Vdc; 11-bit conversion resolution). The rated active power is 200kW under normal duty and 185kW under heavy-duty, with a rated power of 250HP for both conditions.
Nidec
Quick Quote
M701-11602100E10101AB100
NIDEC M701-11602100E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed for variable speed control with a built-in brake transistor, single Safe Torque Off (STO), and requires an external choke with air cooling for operation. It features frame size 11E with dimensions of H46.9" x W12.2" x D48.9" (H1190mm x W310mm x D312mm) and supports RS-485 Modbus RTU communication protocol. The rated current is 225A under normal duty and 210A under heavy-duty conditions, with a supply voltage range of 500Vac-690Vac (600Vac). It operates within an ambient air temperature range of -20°C to +40°C and has a degree of protection of IP20 NEMA 1 UL open. This inverter is designed for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 x analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 3 x digital inputs (0-24Vdc), 3 x digital outputs (0-24Vdc; source) plus 1 x digital output (2A / 240Vac; source; relay contact type), and analog inputs comprising 1 x differential (0-20mA / 4-20mA / -10...+10Vdc; 11-bit conversion resolution) and 2 x single-ended (0-20mA / 4-20mA / -10...+10Vdc; 11-bit conversion resolution). The rated active power is 200kW under normal duty and 185kW under heavy-duty, with a rated power of 250HP for both conditions.
Nidec
Quick Quote
M701-11502850E10101AN100
NIDEC M701-11502850E10101AN100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed for variable speed control with a single Safe Torque Off (STO) and requires an external choke for air cooling. It features dimensions of frame size 11E, measuring H46.9" x W12.2" x D48.9" (H1190mm x W310mm x D312mm), and operates with a communication protocol of RS-485 Modbus RTU. The rated current is 315A under normal duty and 285A under heavy-duty conditions, with a supply voltage range of 500Vac-575Vac. It is designed to operate within an ambient air temperature range of -20°C to +40°C and has a degree of protection rated at IP20 NEMA 1 UL open. This inverter supports a 3-phase input network with a frequency range of 45-66 Hz for supply input and 0-599 Hz for output. It includes 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), and 4 digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type). Additionally, it features 3 analog inputs with varying conversion resolutions and is capable of delivering a rated active power of 250kW under normal duty and 225kW under heavy-duty, equivalent to 350HP and 300HP respectively.
Nidec
Quick Quote
M701-11502540E10101AN100
NIDEC M701-11502540E10101AN100 is a Variable Speed/Frequency Drive (VSD/VFD) from the M701 series designed for variable speed control with a single Safe Torque Off (STO) and requires an external choke for air cooling. It features dimensions of frame size 11E, measuring H46.9" x W12.2" x D48.9" (H1190mm x W310mm x D312mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 288A under normal duty and 254A under heavy-duty conditions. It is designed for a supply voltage range of 500Vac-575Vac and can operate in ambient air temperatures ranging from -20°C to +40°C. The drive offers an IP20 NEMA 1 UL open degree of protection and is suitable for 3-phase input networks with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), 4 digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type), and 3 analog inputs (0-20mA / 4-20mA / -10...+10Vdc; with different conversion resolutions). The rated active power is 225kW under normal duty and 185kW under heavy-duty, corresponding to 300HP and 250HP, respectively.
Nidec
Quick Quote
M701-11502850E10101AB100
NIDEC M701-11502850E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor, single Safe Torque Off (STO), and requires an external choke with air cooling for operation. It features dimensions of frame size 11E, measuring H46.9" x W12.2" x D48.9" (H1190mm x W310mm x D312mm), and utilizes the RS-485 Modbus RTU communication protocol. The rated current is 315A for Normal duty and 285A for Heavy-duty, with a supply voltage range of 500Vac-575Vac. It operates within an ambient air temperature range of -20°C to +40°C and has a degree of protection rated at IP20 NEMA 1 UL open. This VSD/VFD is designed for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 x analog outputs, 3 x digital inputs, 3 x digital outputs, and 3 x analog inputs with varying specifications for signal types and conversion resolutions. The rated active power is 250kW for Normal duty and 225kW for Heavy-duty, corresponding to 350HP and 300HP, respectively.
Nidec
Quick Quote
M701-11502540E10101AB100
NIDEC M701-11502540E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor, single Safe Torque Off (STO), and requires an external choke and air cooling for operation. It features dimensions of frame size 11E, measuring H46.9" x W12.2" x D48.9" (H1190mm x W310mm x D312mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 288A under normal duty and 254A under heavy-duty conditions. It is designed for a supply voltage of 500Vac-575Vac, can function within an ambient air temperature range of -20°C to +40°C, and has a degree of protection rated at IP20 NEMA 1 UL open. The device accommodates a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 x analog outputs, 3 x digital inputs, 3 x additional digital inputs, 3 x digital outputs plus 1 x digital output with relay contact type, and 1 x analog input plus 2 x analog inputs, all specified with their respective signal types and conversion resolutions. The rated active power is 225kW for normal duty and 185kW for heavy-duty, corresponding to 300HP and 250HP, respectively.
Nidec
Quick Quote
M701-11502000E10101AN100
NIDEC M701-11502000E10101AN100 is a Variable Speed/Frequency Drive (VSD/VFD) from the M701 series designed for variable speed control with a single Safe Torque Off (STO) and requires an external choke and air cooling. It features dimensions of frame size 11E, measuring H46.9" x W12.2" x D48.9" (H1190mm x W310mm x D312mm), and operates with a communication protocol of RS-485 Modbus RTU. The drive has a rated current of 248A under normal duty and 200A under heavy-duty conditions, with a supply voltage range of 500Vac-575Vac. It is designed to operate within an ambient air temperature range of -20°C to +40°C and has a degree of protection rated at IP20 NEMA 1 UL open. The network type is a 3-phase input (3P) with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 x analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 3 x digital inputs (0-24Vdc), 3 x digital outputs (0-24Vdc; source) plus 1 x digital output (2A / 240Vac; source; relay contact type), and analog inputs comprising 1 x differential (0-20mA / 4-20mA / -10...+10Vdc; 11-bit conversion resolution) and 2 x single-ended (0-20mA / 4-20mA / -10...+10Vdc; 11-bit conversion resolution). The rated active power is 175kW for normal duty and 150kW for heavy-duty, with corresponding rated power of 250HP and 200HP, respectively.
Nidec
Quick Quote
M701-11502000E10101AB100
NIDEC M701-11502000E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor, single Safe Torque Off (STO), and requires an external choke with air cooling for operation. It features dimensions of frame size 11E, measuring H46.9" x W12.2" x D48.9" (H1190mm x W310mm x D312mm), and utilizes the RS-485 Modbus RTU communication protocol. The rated current is 248A for Normal duty and 200A for Heavy-duty, with a supply voltage range of 500Vac-575Vac. It operates within an ambient air temperature range of -20°C to +40°C and has a degree of protection rated at IP20 NEMA 1 UL open. This VSD/VFD supports a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), 4 digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type), and 3 analog inputs (0-20mA / 4-20mA / -10...+10Vdc; with different conversion resolutions and input types). The rated active power is 175kW for Normal duty and 150kW for Heavy-duty, corresponding to 250HP and 200HP, respectively.
Nidec
Quick Quote
M701-11404640E10101AB100
NIDEC M701-11404640E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor, single Safe Torque Off (STO), and requires an external choke with air cooling for operation. It features dimensions of frame size 11E, measuring H46.9" x W12.2" x D48.9" (H1190mm x W310mm x D312mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 507A under normal duty and 464A under heavy-duty conditions. It is designed for a supply voltage of 380Vac-480Vac (400Vac / 415Vac) and can function within an ambient air temperature range of -20°C to +40°C. The device offers an IP20 degree of protection, NEMA 1 UL open, and is suitable for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), 4 digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type), and 3 analog inputs (0-20mA / 4-20mA / -10...+10Vdc; differential and single-ended; 11-bit conversion resolution). The rated active power is 315kW under normal duty and 250kW under heavy-duty, with a rated power of 450HP (normal duty) and 400HP (heavy-duty).
Nidec
Quick Quote
M701-11404640E10101AN100
NIDEC M701-11404640E10101AN100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a single Safe Torque Off (STO) and requires an external choke and air cooling for operation. It features dimensions of frame size 11E, measuring H46.9" x W12.2" x D48.9" (H1190mm x W310mm x D312mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 507A under normal duty and 464A under heavy-duty conditions. It is designed for a supply voltage of 380Vac-480Vac (specifically 400Vac / 415Vac) and can function within an ambient air temperature range of -20°C to +40°C. The device offers an IP20 NEMA 1 UL open degree of protection and is suitable for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), 4 digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type), and 3 analog inputs (1 x differential and 2 x single-ended; 0-20mA / 4-20mA / -10...+10Vdc; 11-bit conversion resolution). The rated active power is 315kW for normal duty and 250kW for heavy-duty, with corresponding rated power of 450HP and 400HP, respectively.
Nidec
Quick Quote
M701-11404170E10101AN100
NIDEC M701-11404170E10101AN100 is a Variable Speed/Frequency Drive (VSD/VFD) from the M701 series designed for variable speed control with a single Safe Torque Off (STO) feature, requiring an external choke and air cooling for operation. It has dimensions of frame size 11E, measuring H46.9" x W12.2" x D48.9" (H1190mm x W310mm x D312mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 487A under normal duty and 417A under heavy-duty conditions. It is designed for a supply voltage of 380Vac-480Vac (specifically 400Vac / 415Vac) and can function within an ambient air temperature range of -20°C to +40°C. The device offers an IP20 degree of protection and is compatible with a 3-phase input network, with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It features 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), and 4 digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type), along with 3 analog inputs (1 differential and 2 single-ended; both with 11-bit conversion resolution). The rated active power is 250kW under normal duty and 200kW under heavy-duty, corresponding to 400HP and 350HP, respectively.
Nidec
Quick Quote
M701-11404170E10101AB100
NIDEC M701-11404170E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor, single Safe Torque Off (STO), and requires an external choke with air cooling for operation. It features dimensions of frame size 11E, measuring H46.9" x W12.2" x D48.9" (H1190mm x W310mm x D312mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 487A under normal duty and 417A under heavy-duty conditions. It is designed for a supply voltage of 380Vac-480Vac (400Vac / 415Vac) and can function within an ambient air temperature range of -20°C to +40°C. The degree of protection is IP20 NEMA 1 UL open, suitable for 3-phase input (3P) networks with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 x analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 3 x digital inputs (0-24Vdc), 3 x digital outputs (0-24Vdc; source), 1 x digital output (2A / 240Vac; source; relay contact type), and analog inputs comprising 1 x (0-20mA / 4-20mA / -10...+10Vdc; differential; 11-bit conversion resolution) and 2 x (0-20mA / 4-20mA / -10...+10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 250kW under normal duty and 200kW under heavy-duty, with rated power of 400HP (normal duty) and 350HP (heavy-duty).
Nidec
Quick Quote
M701-11403770E10101AB100
NIDEC M701-11403770E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor, single Safe Torque Off (STO), and requires an external choke with air cooling for operation. It features dimensions of frame size 11E, measuring H46.9" x W12.2" x D48.9" (H1190mm x W310mm x D312mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 437A under normal duty and 377A under heavy-duty conditions. It is designed for a supply voltage of 380Vac-480Vac (specifically 400Vac / 415Vac) and can function within an ambient air temperature range of -20°C to +40°C. The degree of protection offered is IP20 NEMA 1 UL open, suitable for 3-phase input (3P) networks with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 x analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 3 x digital inputs (0-24Vdc), 3 x digital outputs (0-24Vdc; source), 1 x digital output (2A / 240Vac; source; relay contact type), and analog inputs comprising 1 x differential (0-20mA / 4-20mA / -10...+10Vdc; 11-bit conversion resolution) and 2 x single-ended (0-20mA / 4-20mA / -10...+10Vdc; 11-bit conversion resolution). The rated active power is 225kW for normal duty and 185kW for heavy-duty, corresponding to 350HP and 300HP, respectively.
Nidec
Quick Quote
M701-11403770E10101AN100
NIDEC M701-11403770E10101AN100 is a Variable Speed/Frequency Drive (VSD/VFD) from the M701 series designed for variable speed control with a single Safe Torque Off (STO) feature, requiring an external choke and air cooling. It has dimensions of frame size 11E, measuring H46.9" x W12.2" x D48.9" (H1190mm x W310mm x D312mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 437A under normal duty and 377A under heavy-duty conditions. It is designed for a supply voltage of 380Vac-480Vac (specifically 400Vac / 415Vac) and can function within an ambient air temperature range of -20°C to +40°C. The device offers an IP20 NEMA 1 UL open degree of protection and is suitable for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It features 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), and 4 digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type). Additionally, it includes 3 analog inputs with varying specifications for conversion resolution and connection type. The rated active power is 225kW under normal duty and 185kW under heavy-duty, corresponding to a rated power of 350HP and 300HP, respectively.
Nidec
Quick Quote
M701-10601780E10101AN100
NIDEC M701-10601780E10101AN100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed for variable speed control with a single Safe Torque Off (STO) and requires an external choke for air cooling. It features dimensions of frame size 10E, measuring H39.7" x W12.21" x D11.42" (H1010mm x W310mm x D290mm), and supports RS-485 Modbus RTU communication protocol. The drive operates with a rated current of 197A under normal duty and 178A under heavy-duty conditions, and it is designed for a supply voltage of 500Vac-690Vac (600Vac). It can function within an ambient air temperature range of -20°C to +40°C and has a degree of protection rated at IP20 NEMA 1 UL open. This model is suitable for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), 4 digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type), and 3 analog inputs (1 differential and 2 single-ended; 0-20mA / 4-20mA / -10...+10Vdc; 11-bit conversion resolution). The rated active power is 185kW for normal duty and 160kW for heavy-duty, equivalent to 250HP and 200HP, respectively.
Nidec
Quick Quote
M701-10601780E10101AB100
NIDEC M701-10601780E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor, single Safe Torque Off (STO), and requires an external choke with air cooling for operation. It features dimensions of frame size 10E, measuring H39.7" x W12.21" x D11.42" (H1010mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 197A under normal duty and 178A under heavy-duty conditions. It is designed for a supply voltage of 500Vac-690Vac (600Vac) and can function within an ambient air temperature range of -20°C to +40°C. The device offers an IP20 NEMA 1 UL open degree of protection and is suitable for a 3-phase input (3P) network with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 x analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 3 x digital inputs (0-24Vdc), 3 x digital outputs (0-24Vdc; source), 1 x digital output (2A / 240Vac; source; relay contact type), and analog inputs comprising 1 x (0-20mA / 4-20mA / -10...+10Vdc; differential; 11-bit conversion resolution) and 2 x (0-20mA / 4-20mA / -10...+10Vdc; single-ended; 11-bit conversion resolution). The rated active power is 185kW under normal duty and 160kW under heavy-duty, with rated power of 250HP (normal duty) and 200HP (heavy-duty).
Nidec
Quick Quote
M701-10601500E10101AN100
NIDEC M701-10601500E10101AN100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed for variable speed control with a single Safe Torque Off (STO) and requires an external choke for air cooling. It features a frame size of 10E with dimensions of H39.7" x W12.21" x D11.42" (H1010mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 172A under normal duty and 150A under heavy-duty conditions. It is designed for a supply voltage of 500Vac-690Vac (600Vac) and can function within an ambient air temperature range of -20°C to +40°C. The device offers an IP20 NEMA 1 UL open degree of protection and is suitable for a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), and 4 digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type). Additionally, it has 3 analog inputs with an 11-bit conversion resolution. The rated active power is 160kW for normal duty and 132kW for heavy-duty, corresponding to a rated power of 200HP and 175HP, respectively.
Nidec
Quick Quote
M701-10501900E10101AB100
NIDEC M701-10501900E10101AB100 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the M701 series designed with a built-in brake transistor, single Safe Torque Off (STO), and requires an external choke with air cooling for operation. It features dimensions of frame size 10E, measuring H39.7" x W12.21" x D11.42" (H1010mm x W310mm x D290mm). This model supports RS-485 Modbus RTU communication protocol and operates with a rated current of 200A under normal duty and 190A under heavy-duty conditions. It is designed for a supply voltage of 500Vac-575Vac, can function within an ambient air temperature range of -20°C to +40°C, and offers a degree of protection rated at IP20 NEMA 1 UL open. The device accommodates a 3-phase input network with a supply input frequency of 45-66 Hz and an output frequency range of 0-599 Hz. It includes 2 analog outputs (0-20mA / 4-20mA / -10...+10Vdc; source; 10-bit conversion resolution), 6 digital inputs (0-24Vdc), 4 digital outputs (0-24Vdc; source and 2A / 240Vac; source; relay contact type), and 3 analog inputs (1 x differential and 2 x single-ended; 0-20mA / 4-20mA / -10...+10Vdc; 11-bit conversion resolution). The rated active power is 150kW for normal duty and 132kW for heavy-duty, with a rated power of 200HP for both operating conditions.
Nidec
Quick Quote
ATV61HD75Y
Schneider Electric ATV61HD75Y is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter from the Altivar 61 series designed for three-phase networks with a supply voltage range of 425-759Vac, including nominal voltages of 480Vac, 500Vac, 600Vac, and 690Vac. It features a built-in EMC filter of class C3, a built-in heatsink, and a coated version for enhanced chemical resistance, conforming to a reinforced version. The device offers a degree of protection of IP20 and UL type 1, with dimensions of H630mm x W320mm x D290mm. It supports a variety of control methods, including U/F ratio adjustment (2 points / 5 points / energy saving), sensorless flux vector control, and vector control without speed feedback, capable of delivering 120% of the nominal motor torque. The rated current is specified at 85A for 500Vac at 2.5kHz, 77A for 575Vac at 2.5kHz, 84A for 690Vac at 2.5kHz, and it can handle up to 102A max. current for 60 seconds. For connectivity, it includes Modbus and CANopen communication protocols, with 5 digital inputs, 1 additional digital input programmable as discrete or PTC input, another digital input for PWR safety, 1 digital output as C/O SPDT relay contact, another digital output as NO relay contact, and two analog inputs. The output frequency range is 0.1-500 Hz, and it also features 1 analog output. The device is designed for wall mounting and operates with a current consumption of 79A at 500Vac, 67A at 600Vac, and 82A at 690Vac, with rated active power of 75kW at 690Vac and 55kW at 500Vac, equivalent to 75HP.
Schneider Electric
Quick Quote
Items per page: